| PRODUCT NAME : | 33dbm 2watt GSM90 1800 dual band phone signal Repeater |
| MODEL : | KT-G/DRP-B25/75-P33-B |
| PRODUCT CATEGORY : | Dual Band Repeater |
| POWER SUPPLY : | AC 110V、AC 220V、DC -48V |
| FREQUENCY : | 890-915MHz/935-960MHz、1710-1785MHz/1805-1880MHz、1850-1910MHz/1930-1990MHz、1920-1980MHz/2110~2170MHz、806 – 821MHz/851 - 866MHz |
| SCENARIOS : | Office、Railway、Scenic、Island、Offshore、Urban road、Supermarket 、Metro、Rural、Suburban、Hospital、Campus、Mine、Oilfield、Tunnel |
| COVERAGE : | 5000sqm、1-3km、1-5KM、5000-50000sqm |
GSM900/DCS1800 2W Band Selective Repeaters(KT-G/DRP-B25/75-P33-B)
Application scenarios
| Items | Testing Condition | Specification | ||
| Uplink | Downlink | |||
| Working Frequency(MHz) | Nominal Frequency | 890 – 915MHz | 935 - 960MHz | |
| 1710 – 1785MHz | 1805 – 1880MHz | |||
| Gain(dB) | Nominal Output Power-5dB | 90±3 | ||
| Output Power (dBm) | GSM modulating signal | 33 | 33 | |
| ALC (dBm) | Input Signal add 20dB | △Po≤±1 | ||
| Noise Figure (dB) | Working in-band(Max. Gain) | ≤5 | ||
| Ripple in-band (dB) | Nominal Output Power -5dB | ≤3 | ||
| Frequency Tolerance (ppm) | Nominal Output Power | ≤0.05 | ||
| Time Delay (us) | Working in-band | ≤5 | ||
| Peak Phase Error(°) | Working in-band | ≤20 | ||
| RMS Phase Error (°) | Working in-band | ≤5 | ||
| Gain Adjustment Step (dB) | Nominal Output Power -5dB | 1dB | ||
| Gain Adjustment Range(dB) | Nominal Output Power -5dB | ≥30 | ||
| Gain Adjustable Linear(dB) | 10dB | Nominal Output Power -5dB | ±1.0 | |
| 20dB | Nominal Output Power -5dB | ±1.0 | ||
| 30dB | Nominal Output Power -5dB | ±1.5 | ||
| Inter-modulation Attenuation (dBc) | Working in-band | ≤-45 | ||
| Spurious Emission(dBm) | 9kHz-1GHz | BW:30KHz | ≤-36 | ≤-36 |
| 1GHz-12.75GHz | BW:30KHz | ≤-30 | ≤-30 | |
| VSWR | BS/MS Port | 1.5 | ||
| I/O Port | N-Female | |||
| Impedance | 50ohm | |||
| Operating Temperature | -25°C ~+55°C | |||
| Relative Humidity | Max. 95% | |||
| MTBF | Min. 100000 hours | |||
| Power Supply | DC-48V/AC220V(50Hz)/AC110V(60Hz)( ±15%) | |||
| Remote Monitoring Function | Real-time alarm for Door Status, Temperature, Power Supply, VSWR, Output Power | |||
| Remote Control Module | RS232 or RJ45 + Wireless Modem + Chargeable Li-ion Battery | |||